postheadericon Clikcontrol

Take control of your PESA routing switcher from your desktop. It's as easy as launching your favorite web broswer!

 

PESA's Clikcontrol™ is an internet routing control system that operates over an Ethernet network distribution system using TCP/IP.   A basic Clikcontrol system supports up to ten simultaneous clients. Each client can have their own user profile giving them access to all or only part of the matrix. Clikcontrol can even be used to control routers in several different locations around the world.

 

The client interface is a JAVA™2.0 application running inside Windows® Internet Explorer™.  Setting up Clikcontrol server software is not complicated; all needed is a web-enabled server PC and an RS232/RS422 port connection to either the 3500PRO or PERC2000 control system.

 

Clikcontrol is perfect for monitoring, production and any remote router control application. It is compatible with the full line of PESA routers and can be used with routers from 8x2 to 512x512 and beyond.

 

Features

 

- Allows source and destination control through a web browser
- Multi-select take or hot-take options
- Unlimited Salvos
- Simple spreadsheet “Cell-Based” format
- Uses Window® based application supporting internet control of PESA routers equipped with a 3500PRO, 3500PRO-LE or PERC2000 system controller, and can also control the Bobcat, Ocelot and LNS-8 routing switchers

 

 

 

 

Note**

1. ClikControl & PERC2000 are not fully compatible.

2. ClikControl supports USERS and historically imported USER infroamtion from the 3500PRO.

3. PERC2000 does not yet support USERS in the same manner as the 3500PRO.

4. Although ClikControl does not support an "export configuration information to ClikControl" feature, there is no USER information exported to ClikControl.

5. A customer can use ClikControl with the PERC2000 as long as they dont care about USERS or USER can be configured separately in ClikControl configuration software.

6. However, if a customer imports the PERC2000 Configuration into ClikControl, then configures USERS independently, the configuration is more or less locked because any changes which are subsequently made to the PERC2000 and exported to ClikControl will cause ClikControl to LOSE the Configured USER ifnformation and they would have to re-enter the USER information manually using the ClikControl configuration software.

 

 

 

 

 

 

 

SEE PESA AT THE FOLLOWING SHOWS